Normal output |
|
|
BPH |
10,000 |
Output max. |
|
|
BPH |
10,500 |
Output min. |
|
|
BPH |
5,000 |
Cycle time |
|
|
sec. |
5.4 |
Total cycle time |
|
|
min. |
13.2 |
Bottle length up to |
inch |
11.102 |
mm |
262 |
Bottle diameter up to |
inch |
2.795 |
mm |
71 |
Bottles per row |
|
|
bottles |
15 |
Total bottles |
|
|
bottles |
2,205 |
Total pocket carriers |
|
|
carriers |
152 |
Pre-soak: |
|
|
|
|
Total duration time |
|
|
sec. |
232.2 |
Actual treatment time |
|
|
sec. |
124.2 |
Caustic: |
|
|
|
|
Total duration time |
|
|
min. |
6.3 |
Bottles filled with caustic solution |
|
|
min. |
4.3 |
Cool down: |
|
|
|
|
Total duration time |
|
|
min. |
4.3 |
Actual treatment time |
|
|
min. |
1.9 |
Actual Spray time: |
|
|
|
|
Hot caustic |
|
|
sec. |
7.2 |
Caustic I |
|
|
sec. |
3.6 |
Caustic II |
|
|
sec. |
14.4 |
Warm-water I |
|
|
sec. |
14.4 |
Warm-water II |
|
|
sec. |
14.4 |
Cold-water |
|
|
sec. |
14.4 |
Fresh water / sanitizer max. |
|
|
sec. |
14.4 |
Tank capacities: |
|
|
|
|
Pre-soak |
gal. |
343 |
m³ |
1.3 |
Caustic I |
gal. |
713 |
m³ |
2.7 |
Caustic II |
gal. |
79 |
m³ |
0.3 |
Warm-water I |
gal. |
79 |
m³ |
0.3 |
Warm-water II |
gal. |
79 |
m³ |
0.3 |
Cold-water |
gal. |
79 |
m³ |
0.3 |
Water consumption for 0.5 l bottles |
gal./h |
528 |
m³/h |
2 |
Heat consumption heating caustic
from 15°C (59°F) to 80°C (176°F) |
|
|
kJ x 1000 |
1,000 |
Heat consumption during operation
maintaining 80°C (176°F) |
|
|
kJ/h x 1000 |
630 |
Connected load approx. |
|
|
kW |
18 |
Gross machine weight approx. |
pounds |
28,660 |
t |
13 |
Consumption figures are based on freshwater temp. 8-13°C (46-55°F), effluent 35-43°C (95-109°F), bottle discharge 28-33°C (82-91°F), room temperature 15°C (55°F), bottle temperature at infeed 15°C (59°F)
Conversion factors: 1000 kJ ? 238.8 kcal ? 0.45 kg (0.99 lb) low pressure steam ? 0.278 kWh