Performance |
bottles/h |
15,000 |
Control range max. |
bottles/h |
15,750 |
Control range min. |
bottles/h |
7,500 |
Cycle time |
sec. |
4.3 |
Running time |
min. |
15.5 |
Bottle length up to |
mm |
262 |
Bottle diameter up to |
mm |
71 |
Bottles per row |
pieces |
18 |
Bottles inside the machine |
pieces |
3,906 |
Bottle cell carrier |
pieces |
222 |
Pre-heating: |
|
|
Total residence time |
sec. |
181.4 |
Treatment time effective |
sec. |
99.4 |
Caustic: |
|
|
Total residence time |
min. |
9.6 |
Bottles filled with caustic soak |
min. |
7.7 |
Cooling down area: |
|
|
Total residence time |
min. |
3.8 |
Treatment time effective |
min. |
1.5 |
Spraying time effective: |
|
|
Hot caustic |
sec. |
5.8 |
Caustic I |
sec. |
2.9 |
Caustic II |
sec. |
11.5 |
Warm-water I |
sec. |
11.5 |
Warm-water II |
sec. |
11.5 |
Cold-water |
sec. |
11.5 |
Fresh-water max. |
sec. |
11.5 |
Container contents: |
|
|
Pre-soaking |
m³ |
1.4 |
Caustic soaking I |
m³ |
1.6 |
Caustic soaking II |
m³ |
7.9 |
Caustic II |
m³ |
0.25 |
Warm-water I |
m³ |
0.25 |
Warm-water II |
m³ |
0.25 |
Cold-water |
m³ |
0.25 |
Water consumption for 0,5 l bottles |
m³/h |
3.0 |
Heat consumption while heating the caustic from 15°C to 80°C |
kJ x 1000 |
2,690 |
Heat consumption while operating, caustic 80°C |
kJ/h x 1000 |
660 |
Power connected load |
kW |
25 |
Operating weight |
t |
27 |
Consumption specifications refer to fresh-water 8-13°C, wastewater 35-43°C, bottle infeed 28-33°,
room temperature 15°C, bottle temperature at infeed 15°C
Exchange ratio: 1000 kJ ≌ 238.8 kcal ≌ 0.45 kg low pressure steam ≌ 0.278 kWh