Normal output |
|
|
BPH |
2,300 |
Output max. |
|
|
BPH |
2,400 |
Output min. |
|
|
BPH |
1,100 |
Cycle time |
|
|
sec. |
7.8 |
Total cycle time |
|
|
min. |
9.2 |
Bottle length up to |
inch |
10.315 |
mm |
262 |
Bottle diameter up to |
inch |
2.795 |
mm |
71 |
Bottles per row |
|
|
bottles |
5 |
Total bottles |
|
|
bottles |
355 |
Total pocket carriers |
|
|
carriers |
76 |
Heat up: |
|
|
|
|
Total duration time |
|
|
sec. |
85.8 |
Actual treatment time |
|
|
sec. |
15.6 |
Caustic: |
|
|
|
|
Total duration time |
|
|
min. |
6.8 |
Bottles filled with caustic solution |
|
|
min. |
4.3 |
Cool down: |
|
|
|
|
Total duration time |
|
|
min. |
2.2 |
Actual treatment time |
|
|
sec. |
25.2 |
Actual Spray time: |
|
|
|
|
Hot caustic |
|
|
sec. |
7.8 |
Caustic II |
|
|
sec. |
7.8 |
Warm-water |
|
|
sec. |
7.8 |
Fresh water / sanitizer max. |
|
|
sec. |
9.6 |
Tank capacities: |
|
|
|
|
Caustic I |
gal. |
238 |
m³ |
0.9 |
Caustic II |
gal. |
40 |
m³ |
0.15 |
Warm-water |
gal. |
40 |
m³ |
0.15 |
Water consumption for 0.5 l bottles |
gal./h |
132 |
m³/h |
0.5 |
Heat consumption heating caustic
from 15°C (59°F) to 80°C (176°F) |
|
|
kJ x 1000 |
300 |
Heat consumption during operation
maintaining 80°C (176°F) |
|
|
kJ/h x 1000 |
300 |
Connected load approx. |
|
|
kW |
5.3 |
Gross machine weight approx. |
pounds |
12,125 |
t |
5.5 |
Consumption figures are based on freshwater temp. 8-13°C (46-55°F), effluent 35-43°C (95-109°F), bottle discharge 28-33°C (82-91°F), room temperature 15°C (55°F), bottle temperature at infeed 15°C (59°F)
Conversion factors: 1000 kJ ? 238.8 kcal ? 0.45 kg (0.99 lb) low pressure steam ? 0.278 kWh