Performance |
bottles/h |
2,500 |
Control range max. |
bottles/h |
2,625 |
Control range min. |
bottles/h |
1,250 |
Cycle time |
sec. |
7.2 |
Running time |
min. |
8.2 |
Bottle length up to |
mm |
262 |
Bottle diameter up to |
mm |
90 |
Bottles per row |
pieces |
5 |
Bottles inside the machine |
pieces |
340 |
Bottle cell carrier |
pieces |
72 |
Pre-heating: |
|
|
Total residence time |
sec. |
57.6 |
Treatment time effective |
sec. |
14.4 |
Caustic: |
|
|
Total residence time |
min. |
5.4 |
Bottles filled with caustic soak |
min. |
3.8 |
Cooling down area: |
|
|
Total residence time |
min. |
2.3 |
Treatment time effective |
min. |
1.3 |
Spraying time effective: |
|
|
Hot caustic |
sec. |
9.6 |
Caustic II |
sec. |
14.4 |
Warm-water |
sec. |
14.4 |
Cold-water |
sec. |
9.6 |
Fresh-water max. |
sec. |
14.4 |
Container contents: |
|
|
Caustic I |
m³ |
1.1 |
Caustic II |
m³ |
0.2 |
Warm-water |
m³ |
0.15 |
Cold-water |
m³ |
0.15 |
Water consumption for 0,5 l bottles |
m³/h |
0.6 |
Heat consumption while heating the caustic from 15°C to 80°C |
kJ x 1000 |
315 |
Heat consumption while operating, caustic 80°C |
kJ/h x 1000 |
290 |
Power connected load |
kW |
6 |
Operating weight |
t |
7 |
Consumption specifications refer to fresh-water 8-13°C, wastewater 35-43°C, bottle infeed 28-33°,
room temperature 15°C, bottle temperature at infeed 15°C
Exchange ratio: 1000 kJ ≌ 238.8 kcal ≌ 0.45 kg low pressure steam ≌ 0.278 kWh