Performance |
bottles/h |
6,700 |
Control range max. |
bottles/h |
7,035 |
Control range min. |
bottles/h |
3,350 |
Cycle time |
sec. |
5.4 |
Running time |
min. |
11.7 |
Bottle length up to |
mm |
262 |
Bottle diameter up to |
mm |
90 |
Bottles per row |
pieces |
10 |
Bottles inside the machine |
pieces |
1,290 |
Bottle cell carrier |
pieces |
134 |
Pre-heating: |
|
|
Total residence time |
sec. |
199.8 |
Treatment time effective |
sec. |
102.6 |
Caustic: |
|
|
Total residence time |
min. |
5.6 |
Bottles filled with caustic soak |
min. |
3.7 |
Cooling down area: |
|
|
Total residence time |
min. |
3.8 |
Treatment time effective |
min. |
1.9 |
Spraying time effective: |
|
|
Hot caustic |
sec. |
7.2 |
Caustic I |
sec. |
3.6 |
Caustic II |
sec. |
14.3 |
Warm-water I |
sec. |
14.3 |
Warm-water II |
sec. |
14.3 |
Cold-water |
sec. |
14.3 |
Fresh-water max. |
sec. |
14.3 |
Container contents: |
|
|
Pre-soaking |
m³ |
1.0 |
Caustic I |
m³ |
2.3 |
Caustic II |
m³ |
0.25 |
Warm-water I |
m³ |
0.25 |
Warm-water II |
m³ |
0.25 |
Cold-water |
m³ |
0.25 |
Water consumption for 0,5 l bottles |
m³/h |
1.3 |
Heat consumption while heating the caustic from 15°C to 80°C (approx. value) |
kJ x 1000 |
920 |
Heat consumption while operating, caustic 80°C (approx. value) |
kJ/h x 1000 |
630 |
Power connected load |
kW |
15.7 |
Operating weight |
t |
12 |
Consumption specifications refer to fresh-water 8-13°C, wastewater 35-43°C, bottle infeed 28-33°,
room temperature 15°C, bottle temperature at infeed 15°C
Exchange ratio: 1000 kJ ≌ 238,8 kcal ≌ 0,45 kg low pressure steam ≌ 0,278 kWh