Normal output |
BPH |
4,000 |
Output max. |
BPH |
4,200 |
Output min. |
BPH |
2,000 |
Cycle time |
sec. |
8.1 |
Total cycle time |
min. |
17.6 |
Bottle length up to |
in. |
10 |
Bottle type |
DWG NO |
T-14224 |
Bottles per row |
bottles |
9 |
Total bottles |
bottles |
1,170 |
Total pocket carriers |
carriers |
136 |
Pre-soak: |
|
|
Total duration time |
sec. |
300.6 |
Actual treatment time |
sec. |
154.4 |
Caustic: |
|
|
Total duration time |
min. |
8.0 |
Bottles filled with caustic solution |
min. |
5.1 |
Cool down: |
|
|
Total duration time |
min. |
5.1 |
Actual treatment time |
min. |
2.7 |
Actual Spray time: |
|
|
Hot caustic |
sec. |
5.4 |
Caustic I |
sec. |
5.4 |
Caustic II |
sec. |
21.6 |
Warm water I |
sec. |
21.6 |
Warm water II |
sec. |
21.6 |
Cold water |
sec. |
21.6 |
Fresh water / sanitizer max. |
sec. |
21.6 |
Tank capacities: |
|
|
Pre-soak |
gal. |
216 |
Caustic I |
gal. |
525 |
Caustic II |
gal. |
50 |
Warm water I |
gal. |
80 |
Warm water II |
gal. |
50 |
Cold water |
gal. |
50 |
Water consumption for 0.5-gal. bottles |
gal./h 530 |
|
Heat consumption heating caustic
from 59°F to 176°F approx. |
kJ x 1000 |
800 |
Heat consumption during operation
maintaining 176°F approx. |
kJ/h x 1000 |
600 |
Connected load approx. |
kW |
19.7 |
Gross machine weight approx. |
pounds |
32,000 |
Consumption figures are based on freshwater temp. 46-55°F, effluent 95-109°F, bottle discharge 82-91°F, room temperature 55°F, bottle temperature at infeed 59°F