Normal output |
BPH |
7,200 |
Output max. |
BPH |
7,200 |
Output min. |
BPH |
3,600 |
Cycle time |
sec. |
5.5 |
Total cycle time |
min. |
15.4 |
Bottle length up to |
in. |
10 |
Bottle type |
DWG NO |
T-14224 |
Bottles per row |
bottles |
11 |
Total bottles |
bottles |
1,859 |
Total pocket carriers |
carriers |
174 |
Pre-soak: |
|
|
Total duration time |
sec. |
203.5 |
Actual treatment time |
sec. |
104.5 |
Caustic: |
|
|
Total duration time |
min. |
9.4 |
Bottles filled with caustic solution |
min. |
5.5 |
Cool down: |
|
|
Total duration time |
min. |
3.9 |
Actual treatment time |
min. |
1.9 |
Actual Spray time: |
|
|
Hot caustic |
sec. |
115.5 |
Caustic I |
sec. |
3.6 |
Caustic II |
sec. |
14.6 |
Warm water I |
sec. |
14.6 |
Warm water II |
sec. |
14.6 |
Cold water |
sec. |
14.6 |
Fresh water / sanitizer max. |
sec. |
14.6 |
Tank capacities: |
|
|
Pre-soak |
gal. |
264 |
Caustic I |
gal. |
1,300 |
Caustic II |
gal. |
80 |
Warm water I |
gal. |
80 |
Warm water II |
gal. |
80 |
Cold water |
gal. |
80 |
Water consumption for 0,5-gal. bottles |
gal./h |
950 |
Heat consumption heating caustic
from 59°F to 176°F approx. |
kJ x 1000 |
1,700 |
Heat consumption during operation
maintaining 176°F approx. |
kJ/h x 1000 |
950 |
Connected load approx. |
kW |
19.7 |
Gross machine weight approx. |
pounds |
45,000 |
Consumption figures are based on freshwater temp. 46-55°F, effluent 95-109°F, bottle discharge 82-91°F, room temperature 55°F, bottle temperature at infeed 59°F
Conversion factors: 1000 kJ =~ 238.8 kcal =~ 0.99 lb low pressure steam =~ 0.278 kWh